Siti Aishah Rashid1*, Nabilla Athieqa Mahdzar1, Nurul Amalina Khairul Hasni1, Khayri Azizi Kamel2, Raheel Nazakat1, Mohd Ishtiaq Anasir2, Sakshaleni Rajendiran1, Mohamad Iqbal Mazeli1, Yuvaneswary Veloo1, Syahidiah Syed Abu Thahir1, Wan Rozita Wan Mahiyuddin3, Reethiya Letchumanan4, Redzuan Zainudin1, Rafiza Shaharudin1
1. Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia.
2. Infectious Disease Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia
3. SEAMEO TROPMED Network Malaysia, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia
4. Malaysian Prison Department, Ministry of Home Affairs of Malaysia
*Corresponding Author: Siti Aishah Rashid.
ABSTRACT
INTRODUCTION: Coronavirus disease 2019 (COVID-19) and other airborne diseases can spread quickly in crowded, poorly ventilated spaces like prisons. Wastewater-based surveillance (WBS) provides a simple and effective way to track the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in these high-risk settings, where regular clinical testing is limited.
OBJECTIVE(S): This study aimed to evaluate the performance of different viral concentration methods and assays in WBS for SARS-CoV-2 detection in a prison facility in Selangor, Malaysia. Specifically, we compared two concentration techniques Direct Capture (DC) and Electronegative Membrane Filtration (EMF) in term of their ability to recover viral RNA and detect SARS-CoV-2 N1 and N2 gene targets.
MATERIALS & METHODS: Between April and August 2023, a total of 50 sewage samples were collected and processed using both DC and EMF methods. SARS-CoV-2 RNA concentrations were quantified using reverse transcription digital PCR (RT-dPCR), targeting the N1 and N2 regions.
RESULTS: The DC method consistently yielded significantly higher RNA concentrations than EMF. For the N1 gene, DC achieved a median concentration of 1.11 (IQR: 3.87), compared to 0.07 (IQR: 0.40) for EMF, demonstrating a moderate-to-strong positive correlation between methods (ρ = 0.660, p < 0.001). For the N2 gene, DC had a higher median of 0.34 (IQR: 1.15), compared to EMF with 0.05 (IQR: 0.22), with a moderate correlation (ρ = 0.534, p < 0.001). The Wilcoxon Signed Ranks Test further confirmed that DC had higher detection rates than EMF in 92% of samples for N1 (Z = -5.755, p < 0.001) and in 74% for N2 (Z = -4.701, p < 0.001).
CONCLUSION: The DC method demonstrated superior viral RNA recovery compared to EMF, enhancing sensitivity in SARS-CoV-2 detection from wastewater. These findings support the use of DC-based WBS in prison and other resource-limited settings for early warning and public health response.
KEYWORDS: Wastewater-based Surveillance, SARS-CoV-2, RNA, Concentration Method